1.6T OSFP224 InfiniBand XDR

2 Results

Sort by:

1.6T OSFP224 InfiniBand XDR Overview

The 1.6T OSFP224 InfiniBand XDR category contains two single-mode optical transceiver modules for 1.6Tb/s links in InfiniBand XDR end-to-end systems. Both models use the OSFP224 form factor with a finned-top thermal design, PAM4 modulation, 1310nm optics, and DOM support. Designed for Quantum-X800 air-cooled and liquid-cooled switches, the modules primarily connect two switches in supercomputing and high-performance computing environments, including compute and storage infrastructure. The series includes no multimode models and two single-mode models, covering transmission distances from 500m to 2km with either dual MTP/MPO-12 APC or dual duplex LC connectors.
Model Thermal Design Form Factor Fiber Type Data Rate Max. Reach Connector
OSFP-XDR-2DR4 Finned Top OSFP224 SMF 1600G 500m Dual MTP/MPO-12 APC
OSFP-XDR-2FR4 Finned Top OSFP224 SMF 1600G 2km Dual LC Duplex UPC

FAQ

What is a 1.6T OSFP224 InfiniBand XDR transceiver?

A 1.6T OSFP224 InfiniBand XDR transceiver is a high-speed optical module designed for next-generation InfiniBand XDR networks in AI, HPC, and large-scale data center environments. It uses the OSFP224 form factor and supports 1.6Tb/s aggregate bandwidth, helping connect GPU servers, switches, and compute clusters with low-latency, high-density optical links.

What is the difference between 2xDR4/DR8 and 2xFR4/FR8?

2xDR4/DR8 modules are typically designed for shorter single-mode fiber links, such as up to 500m, and use dual MTP/MPO-12 APC connectors. 2xFR4/FR8 modules are designed for longer reaches, such as up to 2km, and commonly use dual LC duplex connectors. The right choice depends on your link distance, cabling infrastructure, connector type, and switch-to-server or switch-to-switch deployment design.

Which reach should I choose: 500m or 2km?

Choose 500m 2xDR4/DR8 modules when your deployment is within the same data hall, between nearby racks, or across short single-mode fiber runs. Choose 2km 2xFR4/FR8 modules when you need longer-distance connections between rooms, buildings, zones, or larger campus data center areas. If you are unsure, confirm the actual fiber distance, connector type, patch panel design, and link budget before selecting the module.

Are these modules suitable for AI and HPC clusters?

Yes. 1.6T OSFP224 InfiniBand XDR transceivers are suitable for AI training clusters, HPC systems, GPU fabrics, and high-bandwidth data center interconnects that require fast, stable, and scalable optical connectivity. They are especially relevant for environments where high throughput, low latency, dense port deployment, and reliable thermal performance are important.